Ozone Generator, PA600

PA 600 Industrial Ozone Generator

Eliminates odors and kills pathogens

$475.00

Ozone Generator, PA600

Category

Description

PA 600 Industrial Ozone Generator

MANUAL

FEATURES AND SPECIFICATIONS

  • An easily programmed timer
  • 600 milligrams of Ozone per hour (measured with free air not pure O2 input)
  • Beige Hammertone scratch resistant aluminum cabinet
  • Low maintenance parallel plate generators powered by 5000-volt heavy duty transformer
  • Size: 14” long, 9” wide, 5.5” high. (36cm long x 23cm wide x 14cm high)
  • Weight: 10 lbs (5 kg)
  • Fan: 105 CFM. (3.0 m³/min)
  • Power Requirement: 120 volt/53 watt/60 hertz
  • Warranty: 2-year warranty

 

OZONE LEVEL CONTROL

  1. Review the FORMULA below and then:
  2. Set OZONE to desired setting
  3. Set TIMER to the desired setting
  4. Plug the unit into any convenient wall socket
  5. Switch the power to ON
  6. Monitor odor level and adjust output as required to control

 

The following formula and chart is suggested as a general guideline only. Use of the formula and chart will enable the user to determine the approximate milligrams per hour (MG/HR) of ozone required to odor situations. Ozone output will vary substantially with changes in temperature and humidity.  AREA x ODOR FACTOR = MG/HR required PA600 MG/HR (Milligrams per hour in dry air)

 

OZONE OUTPUT AT SETTING

190     234     277      321      364      408     451     495     538     582     625

LO         1           2           3          4           5          6          7          8          9        HI

CUBIC METERS

  1. Measure the Cubic Meters (L x W x H) of the AREA being treated
  2. Estimate the ODOR FACTOR as follows:  Light Odor Factor = 0.18 Medium Odor Factor = 0.65 Strong Odor Factor = 1.29
  3. Multiply the AREA by the ODOR FACTOR to determine the MG/HR on the chart below
  4. Set OZONE on the machine to the setting nearest the required MG/HR and adjust as required.
CUBIC FEET

  1.  Measure the Cubic Footage (L x W x H) of the AREA being treated
  2. Estimate the ODOR FACTOR as follows:  Light Odor Factor = 0.005 Medium Odor Factor = 0.018 Strong Odor Factor = 0.036
  3. Multiply the AREA by the ODOR FACTOR to determine the MG/HR on the chart below
  4. Set OZONE on the machine to the setting nearest the required MG/HR and adjust as required.

 

Example:

285 cubic meter room x 1.29 Strong Odor Factor = 368 MG/HR.  Set OZONE at 4 (364 MG/HR) and adjust as required.

Example:

10,000 cubic foot room x 0.036 Strong Odor Factor = 360 MG/HR. Set OZONE at 4 (364 MG/HR) and adjust as required.

OTHER APPLICATIONS                  TIME                 OZONE

Now Car Freshening                              1 HR.                     HI

Used Car Deodorizing                           2 HR.                     HI

(In extreme cases, 2 to 4 consecutive daily automobile treatments may be required).

Taxi/Limousine Deodorizing               2 HR.                    HI

Bus Deodorizing                                     4 HR.                    HI

Paint Odor Removal                            4 – 6 HR            LO ‑ HI

New Carpet Odor Removal                 2 ‑ 4 HR              6 – HI

Room freshening (up to 400 sq.ft.)    15 min.              6 ‑ HI

Hotel Suite (up to 800 sq.ft.)               30 min.            6 ‑ HI

Mold, Mildew, Heavy Room Odors      1 HR.                  HI

Conference Room (up to 2000 sq.ft.)   2 HR.             4 ‑ HI

Restaurant/Bar/Lounge after hours     4 HR.               HI

 

 

 

 

 

Reviews

There are no reviews yet.

Be the first to review “Ozone Generator, PA600”

Your email address will not be published. Required fields are marked *